EU MDR 2017/745 Compliance Guide For Medical Oxygen Generator Manufacturers

Sep 02, 2026

Leave a message

The European Union's Medical Device Regulation 2017/745 (EU MDR) came into

full application on May 26, 2021, replacing the Medical Device Directive

(MDD) that had governed medical device approvals since 1993. For

manufacturers of medical oxygen generators, the transition from MDD to MDR

represented more than a paperwork update - it fundamentally changed the

evidentiary burden required to place a medical device on the European

market.

This article provides a practical compliance overview for oxygen generator

manufacturers targeting EU market access. It assumes you understand the

basics of medical device regulation. What follows focuses on the specific

provisions most relevant to PSA, VPSA, and VSA oxygen generation systems.

news-800-479

Classification: Why Oxygen Generators Are Class IIb

Under EU MDR Annex VIII, medical oxygen generators are classified as Class

IIb devices. The classification rationale is straightforward: the device

supplies a gas that is administered to patients (Rule 11 of Annex VIII -

active devices intended to administer or exchange substances), and the gas

is delivered via a pipeline system that connects directly to patient

interfaces (ventilators, anesthesia machines, flowmeters).

Class IIb classification means your conformity assessment route requires

involvement of a Notified Body - you can't self-declare conformity. You

either follow Annex IX (quality management system audit) combined with

Annex XI (production quality assurance), or Annex X (type examination)

combined with Annex XI.

What's new under MDR vs MDD for oxygen generator manufacturers:

- More stringent clinical evaluation requirements (Annex XIV)

- Mandatory post-market surveillance (PMS) system with periodic safety

update reports (PSUR)

- Unique Device Identification (UDI) marking and registration in EUDAMED

database

- Enhanced requirements for the Person Responsible for Regulatory

Compliance (PRRC)

- Stricter rules on economic operators - importers and distributors now

share regulatory obligations

 

Technical Documentation: The Oxygen-Specific Sections

Annex II of the MDR details what your technical documentation must

contain. For oxygen generators, the following sections require particular

attention:

Device Description and Specification

Beyond listing components, you need to explain the principle of operation

clearly enough that a Notified Body reviewer can understand the full air

separation pathway: intake filtration, compression, drying/cooling,

molecular sieve adsorption, oxygen collection, purity monitoring, pipeline

delivery. Include process flow diagrams with instrumentation marked.

Specify the molecular sieve type (calcium, sodium, or lithium-based).

Design and Manufacturing Information

Provide design calculations for the adsorption tower sizing, cycle timing

optimization, and pressure vessel compliance where applicable. Note: VPSA

and VSA systems operating below 0.1 MPa typically fall below pressure

vessel thresholds. Include material specifications demonstrating oxygen

compatibility - all materials in contact with oxygen-enriched gas must

meet oxygen cleaning and compatibility standards (ISO 15001 or equivalent).

General Safety and Performance Requirements (GSPR)

Annex I of the MDR lists 23 GSPRs. For oxygen generators, pay special

attention to:

- GSPR 10 (substances): demonstrate that no oil or other contaminants

leach into the product gas from the compression process. Oil-free

compressor designs simplify this demonstration considerably.

- GSPR 11 (infection and microbial contamination): describe the

filtration and sterilization measures in the oxygen pathway.

- GSPR 14 (construction and interaction with environment): address fire

safety in oxygen-enriched environments.

- GSPR 17 (software): if your system includes intelligent control

software with automatic parameter adjustment, this software is a medical

device in its own right under MDR and must comply with IEC 62304.

Clinical Evaluation Under MDR

This is where many oxygen generator manufacturers struggle. Under MDD,

manufacturers could often demonstrate equivalence to existing devices and

rely on literature reviews. MDR tightens this substantially.

For oxygen generators, you'll need:

1. A systematic literature review demonstrating that 93 percent plus or

minus 3 percent oxygen generated by PSA/VPSA/VSA technology is clinically

safe and effective. Fortunately, this evidence base is robust - ISO 10083,

the US Pharmacopoeia (Oxygen 93 Percent), and the European Pharmacopoeia

all recognize this oxygen specification for medical use, with over 30

years of global clinical experience.

2. If claiming equivalence to an existing device, you need a contract with

the manufacturer of that device granting full access to their technical

documentation.

3. Post-market clinical follow-up (PMCF) data from your own installed

base. MDR expects you to proactively collect and analyze clinical data

from devices in use, not just wait for adverse event reports.

Post-Market Surveillance (PMS)

MDR Articles 83-86 establish PMS requirements that effectively turn every

installed oxygen generator into a data source. Your PMS system must

collect:

- Oxygen purity and output consistency data over time

- Unscheduled maintenance events and root cause analyses

- Customer complaints and their resolutions

- Any incidents involving patient harm or near-misses

For manufacturers with intelligent monitoring platforms (such as LBYL

Medical's IoT-based system), collecting this data is relatively

straightforward - the system already records performance parameters. For

manufacturers without remote monitoring, collecting PMS data requires a

more manual process.

Practical Steps Toward MDR Compliance

If you're a manufacturer currently targeting EU market access, here's the

prioritized action list:

1. Engage a Notified Body early. Don't wait until your technical

documentation is perfect. Start the conversation 12-18 months before you

need to be on the market.

2. Audit your clinical evidence gap. Most oxygen generator manufacturers

have strong preclinical testing data but relatively thin clinical

evaluation reports. The clinical evaluation is now the most common reason

for MDR certification delays.

3. Implement your PMS system before you need the data. Install remote

monitoring on existing systems now, not when the Notified Body asks for 2

years of surveillance data.

4. Get your UDI system in place. Register your devices in EUDAMED.

5. Review your economic operator agreements. Under MDR, your EU Authorized

Representative, importers, and distributors all carry regulatory

obligations.

MDR compliance for oxygen generators is demanding but achievable. The

manufacturers who navigate it successfully will find themselves in a

European market with higher barriers to entry - and consequently, less

price competition from manufacturers who can't or won't make the

investment.